Individual data files are provided for each figure in the paper. For figures with a large number of sub-panels, a separate file is provided for each sub-panel. All data files are in ASCII format. Names of the variables are indicated in each data file for each curve. When available, uncertainty data are also provided for each set of data. When applicable, units are indicated with the variable they refer to. ========================================================================= Figure 1 For panels (a) and (b), only the geometry data of lines of sight of FIDA diagnostic are provided. The data about tiles and vessel are not given here. Figure 2 Data of CCD frame from experimental measurement is given. Figure 3 Panel a : Data for transmission curve and raw spectrum are given Panel b and c: The sets of data are given, which refer to the dependence of the CCD counts on cold D_alpha line intensity. Figure 4 The data for the scattering level test is given are given. Figure 5a,b The spectra of active and reference views at R=90cm for shot204092 are given Figure 6 Panels (a), (b) and (c) provide the plasma current, density and temperature data, respectively. (d) and (e) compare the measured baseline and the simulated bremsstrahlung emission, and the related data are given. Figure 7 The data for the baselines of v- and t-FIDA at several major radii are given. In addition, the data of the gap between plasma and vessel is given, as shown in panel (e). Figure 8 The data for all of the panels are given. Figure 9 The data from experiment and the data for the fitter line are given. Figure 10 (a) The beam waveform data is given; For (b), the measured raw signals are given. For (c), the measured raw signal and the related uncertainty are given. Figure 11 For panel (a), the averaged CCD counts over 81 fiducial shots at boundary pixel of CCD chip before and after making scattering correction and the related uncertainty are given. For panel (b), the count number for baseline with and w/o correction and the related uncertainty are given. Figure 12 The data for experimental and the simulated spectra and the related uncertainty are given. Figure 13 The data for experimental and simulated profile of v-FIDA are given. Figure 14 The data for the experimental spectra in the red side of Doppler-shift with and w/o scattering correction and the uncertainty are given. The data for simulated spectrum are also provided. Figure 15 The data for all of the curves and the related uncertainty are given. Figure 16 (a)Obtained CCD whole frame in the on-bench test when one fiber is illuminated. (b) The contamination on the blind side of the CCD chip Figure 17 (a)Comparison of the scattering coefficient for the boundary pixel vs. illuminated fiber as determined with a D_alpha lamp in the laboratory and through the SVD analysis of plasma discharges. (b) Comparison of the average cold D_alpha light that was employed in the SVD analysis with the measured intensity of the D¦Á lamp (multiplied by 1000) vs. fiber. Figure 18 Time evolution of the measured net baseline and corrected ones using SVD, and D_alpha lamp for the fiber at R = 117 cm. Here, the net baseline value is estimated by the difference of the measured baseline at the active and reference views. The baseline is defined as the mean counts in the wavelength range 661.5-661.8 nm in the red-shift side.